* Configuration values for ModularWeatherStation
|
||
*
|
||
* Copyright (C) 2021 Gergely Polonkai
|
||
* Author: Gergely POLONKAI <gergely@polonkai.eu>
|
||
*
|
||
* ModularWeatherStation is free software: you can redistribute it
|
||
* and/or modify it under the terms of the GNU General Public License
|
||
* as published by the Free Software Foundation, either version 3 of
|
||
* the License, or (at your option) any later version.
|
||
*
|
||
* ModularWeatherStation is distributed in the hope that it will be
|
||
* useful, but WITHOUT ANY WARRANTY; without even the implied warranty
|
||
* of MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
|
||
* GNU General Public License for more details.
|
||
*
|
||
* You should have received a copy of the GNU General Public License
|
||
* along with this program. If not, see <http://www.gnu.org/licenses/>.
|
||
*
|
||
* As additional permission under GNU GPL version 3 section 7, you may
|
||
* distribute non-source form of the Program without the copy of the
|
||
* GNU GPL normally required by section 4, provided you inform the
|
||
* receipents of GNU GPL by a written offer.
|
||
*
|
||
*/
|
||
|
||
// The SSID (name) and password of the WiFi network you want to connect to
|
||
#define WIFI_SSID "YourWiFiName"
|
||
#define WIFI_PASS "YourWiFiPass"
|
||
|
||
// The mDNS hostname you want this station to be visible as. This should be
|
||
// different for each station you install (e.g. if you want to measure the
|
||
// temperature and humidity of each room separately)
|
||
#define MDNS_NAME "internal-hostname"
|
||
|
||
// If you have a DHT temperature+humidity sensor of this type will be used,
|
||
// remove the #undef line and uncomment one of DHT11 or DHT22. You also have
|
||
// to define the PIN your DHT sensor’s data (usually marked as DAT) is
|
||
// connected to.
|
||
//
|
||
// DHT11 sensors are usually blue, and don’t work under freezing point
|
||
// (0°C/32°F)
|
||
//
|
||
// DHT22 sensors are usually white and slightly bigger than DHT11 ones. They
|
||
// work well under freezing point (usually above -40°C/-40°F)
|
||
#undef DHT_TYPE
|
||
//#define DHT_TYPE DHT11
|
||
//#define DHT_TYPE DHT22
|
||
//#define DHT_PIN D5
|
||
|
||
// If you have a rain sensor (FC-37 or YL-83), connect its digital pin (not the
|
||
// analogue one!), remove the #undef line, and uncomment and change the
|
||
// #define RAIN_PIN line
|
||
#undef RAIN_PIN
|
||
//#define RAIN_PIN D0
|